There is an electrical distribution box next to the balcony

What Are the Electrical Code Requirements for Exterior Outlets?

The National Electrical Code specifies precise areas around a dwelling where exterior receptacles must be installed. For one-family and two-family homes, at least one 125-volt, 15- or 20

Receptacle Outlet Requirements for Balconies, Decks

The revised Code now requires that a receptacle be installed to serve the balcony, deck, or porch when the balcony, deck, or porch is within 4 inches of the dwelling unit.

Receptacle Outlet for Balconies, Decks, and Porches | Captain Code

The receptacle must be located in an accessible location from the balcony, deck, or porch and not more than 2.0 m (6½ ft) above the balcony, deck, or porch walking surface.

NEC Rules for Outdoor Wiring

Decks, balconies, and porches attached to the home and accessible from indoors must have at least one receptacle. The outlet must be placed no more than 6.5 feet above the walking

Service and Meter Clearances can Vary! – InterNACHI Inspection

Clearances specified in these narratives are from the National Electric Code (NEC). Local electrical utilities may have standards that take precedence over NEC standards. You should take the time to

National Electrical Code (NEC) Rules for Outdoor Wiring

Attached decks and balconies with interior access (including a door to the indoors) must have a receptacle no more than 6 1/2 feet above the deck or balcony walking surface.

Balconies and porches within 4",,, | Information by Electrical

All porches, balconies etc. should have one receptacle so long as they are attached or close enough (within 4") of the dwelling unit.

What is code requirement for receptacle outlets at a porch, deck, or

At least one receptacle outlet is required for any porch, deck, or balcony that is within 4-inches horizontally of a house, according to the 2020 edition of the National Electrical Code [NEC

Receptacle Outlet for Balconies, Decks, and Porches

The receptacle must be located in an accessible location from the balcony, deck, or porch and not more than 2.0 m (6½ ft) above the balcony, deck, or porch walking

receptacle

In other words, there needs to be a readily accessible receptacle not more than 6.5'' above the walking level in front, in back, and for each balcony, deck, or porch you have.

210.52 (E) (3) Balconies, Decks, and Porches.

Balconies, decks, and porches that are attached to the dwelling unit and are accessible from inside the dwelling unit shall have at least one receptacle outlet accessible from the balcony, deck, or porch.